TBS Omnicharge Specifications

Truecharge2 Battery Charger

General Technical Data (TBS Omnicharge)
Model Omnicharge 12v 40amp Charger Omnicharge 12v 60amp Charger Omnicharge 24v 20amp Charger Omnicharge 24v 30amp Charger
Enerdrive Code OC12-40 OC12-60 OC24-20 OC24-30
Input voltage 100 - 260VAC / 47 - 63Hz / PF ≥ 0.95
Full load consumption 700VA 1050VA 700VA 1050VA
AC input current (115V / 230V) 6A / 3A 9A / 5.4A 6A / 3A 9A / 5.4A
Full load efficiency 88% 88% 91% 91%
Nominal output voltage 1) 12V 24V
Total output current 1) 4) (Aux.) 40A (4A) 60A (4A) 20A (2.5A) 30A (2.5A)
Charge characteristic 2) IUoUop, intelligent 4 stage, temperature compensated
Absorption voltage 2) 14.4V 28.8V
Float voltage 2) 13.5V 27.0V
Equalize voltage 2) 15.5V 31.0V
Supported battery types 2) Flooded / GEL / AGM / Custom
Recommended battery capacity 2) 80 - 400 Ah 120 - 600 Ah 50 - 200 Ah 70 - 300 Ah
DC current draw (charger off) ≤ 5mA ≤ 4MA
Operating temperature range 4) -20°C to 50°C (humidity max. 95% non condensing)
Storage temperature range -40°C to 80°C (humidity max. 95% non condensing)
Cooling Variable speed fan controlled by temperature and load
TBS Link enabled Yes
Protected against Low AC voltage, output short circuit, high temperature, battery overcharging and reverse polarity (fuse)
Indications Power on, output current bar, state of charge bar, error
DC output connections M8 bolts (main output), Screw terminals (auxiliary output)
AC input connections Screw terminals
Enclosure body size 351 x 210 x 114 mm
Total weight 5.8kg
Protection class IP21 (mounted in upright position)
Standards CE market meeting EMC directive 2004/108/EC and LVD 2006/95/EC complying with EN60335-1, EN60335-2-29

1) Maximum output current tollerance is +/- 3%. Maximum setpoint voltage deviations are +/- 0.1V for 12V and +/- 0.2V for 24V models. All setpoint voltages are temperature compensated when battery temperature sensor is connected 2) Value is programmable 3) Always consult battery manufactures specifications for maximum allowable charge current. 4) At higher ambient temperatures (>40°C), maximum output current may be reduced automatically

Optional Accessories
Enerdrive Code URC-TBS TBS Dashboard
Model TBS Universal Remote Control Panel TBS Dashboard Software
Dimensions (H x W x L) 130 x 70 x 48mm
Cut Out Dimensions 113 x 58 x 30mm - (Diameter x Intrusion)
Display LCD
Operating Temperature Range -10°C to 50°C
Weight 140gm
Warranty 2 year