XW System Specifications

| Model - Description | XW Hybrid Inverter Charger 4.0Kw/24v-150amp Charger | XW Hybrid Inverter Charger 4.5Kw/48v-85amp Charger | XW Hybrid Inverter Charger 6.0Kw/48v-100amp Charger |
|---|---|---|---|
| Enerdrive Code | 865-1045 | 865-1040 | 865-1035 |
| Output Power (continuous) | 4000W | 4500W | 6000W |
| Surge Capacity (Peak) | 8000W | 9000W | 12000W |
| Surge Current | 35 A rms | 40 A rms | 53 A rms |
| Waveform | True sine wave | True sine wave | True sine wave |
| AC Connections | AC1 Grid, AC2 Generator | AC1 Grid, AC2 Generator | AC1 Grid, AC2 Generator |
| AC Input Voltage Range (bypass / charge mode) | 156 to 280Vac, (230Vac Nominal) | 156 to 280Vac, (230Vac Nominal) | 156 to 280Vac, (230Vac Nominal) |
| AC Input Frequency (bypass / charge mode) | 40 to 68Hz (50Hz Nominal) | 40 to 68Hz (50Hz Nominal) | 40 to 68Hz (50Hz Nominal) |
| AC Output Voltage | 230Vac ± 3% | 230Vac ± 3% | 230Vac ± 3% |
| Maximum AC pass though current | 56A | 56A | 56A |
| AC Output Continuous Current | 17,4 A | 19,6 A | 26,1 A |
| AC OutPut Frequency | 50 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz |
| Total Harmonic Distortion | < 5% at rated power | < 5% at rated power | < 5% at rated power |
| Peak Efficiency | 94.0% | 95.6% | 95.4% |
| No Load Current Draw (search mode) | < 7 W | < 7 W | < 7 W |
| Typical Transfer Time | 8 ms | 8 ms | 8 ms |
| DC Current at Rated Power | 178 A | 96 A | 131 A |
| Uitilty-Interactive | Disabled (default) AC voltage range 198 to 253 Vac, AC frequency range 49.1 to 50.9 Hz | ||
| DC Input Voltage Range | 22 to 32 V | 44 to 64 V | 44 to 64 V |
| Continuous Charge rate | 150 A | 85 A | 100 A |
| Power Factor Corrected Charging | PF (0.98) | PF (0.98) | PF (0.98) |
| Mounting Bracket | Wall Mount Included | Wall Mount Included | Wall Mount Included |
| Supported Battery Types | Flooded (default), Gel AGM, Custom | ||
| Battery Bank Size | 100 to 10,000 Ah | ||
| Battery Temperature Sensor | Included | ||
| Non Volatile Memory | Yes | ||
| Display Panel | Status LEDs indicate AC In status, faults / warnings, equalize mode, On/Off and equalise button battery level, Three character display indicates output power or charge current | ||
| Multiple Unit Configurations | Single phase: Up to 3 parallel units: Three Phase: 1 unit per phase | ||
| System Network | Xanbus™ | ||
| Enclosure Type | IP20 (sensitive electric components sealed inside enclosure | ||
| Operational Temperature Range | (!) - 25 to 70°C | ||
| Dimensions (H x W x L) | 580 x 410 x 230mm | 580 x 410 x 230mm | 580 x 410 x 230mm |
| Weight | 52kg | 52kg | 57kg |
| Warranty | 5 years | 6 years | 7 years |
| Accessories | |||
|---|---|---|---|
| 865-1050 | 865-1030-01 | 865-1060 | 865-1025 |
| XW System Control Panel | XW 60amp Maximum Power Point Tracker | XW Automatic Generator Start Controller | XW Conduit Box |